Compact, reliable and efficient, it will act as a small boiler
room at an affordable price. This system will provide hot water for the central heating
system as well as Domestic Hot water supply.
|
| Model | Termal |
DHW Flow | Pipe Connections | Circulation Pump (3 Speed) |
Flue |
Weight Kg |
Dimension (H-W-D) Cm |
||||||
| Kcal/Hr. | KW | L/Min | GPM | C.H.S in-out |
Gas | D.H.W. in-out |
RPM | W | AMP | ||||
| AGB-40 | 40,000 | 47 | 14 | 3.7 | 1"-1" | 3"/4 | ½"-½" | 1050 1400 1800 |
60 83 110 |
0,27 0.37 0.48 |
10 | 135 | 85-50-70 |
| AGBE-40 | 40,000 | 47 | 14 | 3.7 | 1"-1" | 3"/4 | ½"-½" | 1050 1400 1800 |
60 83 110 |
0,27 0.37 0.48 |
10 | 135 | 85-50-70 |
| AFB-70 | 70,000 | 82 | 18 | 4.7 | 1"-1" | ** | ½"-½" | 1050 1400 1800 |
60 83 110 |
0,27 0.37 0.48 |
10 | 225 | 85-74-120 + * Panel |
* Panel = 15 cm
* * Recommended burner for this application :
Gas burner model AMG(80,000 kcal/hr)
Oil burner model AML (1-3 Gpm)